Pressure Sensor Load Cell 10kg and HX711 amplifier 10KG

TZT Load Cell 10KG HX711 AD Module Weight Sensor Electronic Scale Aluminum Alloy Weighing Pressure Sensor


30 ₪

الناشر: ⚡ Electronic Store ⚡

القسم: Sensors

تاريخ النشر: 2022-06-01





الشكل الواقعي عند التركيب



connection

==========load cell interface to hx711========== Red: E+ Black: E- Green: A- White: A+ ================================================ ============ hx711 interface to RPI ============ VCC to Raspberry Pi Pin 2 (5V) GND to Raspberry Pi Pin 6 (GND) DT to Raspberry Pi Pin 29 (GPIO 5) SCK to Raspberry Pi Pin 31 (GPIO 6) ================================================





example code:

code
نسخ
اقتباس
عرض
تنزيل
	
								
#! /usr/bin/python2 import time import sys # HOW TO CALCULATE THE REFFERENCE UNIT # In this case, 92 is 1 gram because, with 1 as a reference unit I got numbers near 0 without any weight # and I got numbers around 184000 when I added 2kg. So, according to the rule of thirds: # If 2000 grams is 184000 then 1000 grams is 184000 / 2000 = 92. referenceUnit = 113 import RPi.GPIO as GPIO from hx711_lib import HX711 #import this from file "hx711_lib.py" def cleanAndExit(): print("Cleaning...") if not EMULATE_HX711: GPIO.cleanup() print("Bye!") sys.exit() hx = HX711(5, 6) hx.set_reading_format("MSB", "MSB") hx.set_reference_unit(referenceUnit) hx.reset() hx.tare() print("Tare done! Add weight now...") while True: try: val = abs(hx.get_weight(5)) print(val) hx.power_down() hx.power_up() time.sleep(0.1) except (KeyboardInterrupt, SystemExit): cleanAndExit()





library file ==> hx711_lib.py

code
نسخ
اقتباس
عرض
تنزيل
	
								
# import RPi.GPIO as GPIO import time import threading class HX711: def __init__(self, dout, pd_sck, gain=128): self.PD_SCK = pd_sck self.DOUT = dout # Mutex for reading from the HX711, in case multiple threads in client # software try to access get values from the class at the same time. self.readLock = threading.Lock() GPIO.setmode(GPIO.BCM) GPIO.setup(self.PD_SCK, GPIO.OUT) GPIO.setup(self.DOUT, GPIO.IN) self.GAIN = 0 # The value returned by the hx711 that corresponds to your reference # unit AFTER dividing by the SCALE. self.REFERENCE_UNIT = 1 self.REFERENCE_UNIT_B = 1 self.OFFSET = 1 self.OFFSET_B = 1 self.lastVal = int(0) self.DEBUG_PRINTING = False self.byte_format = 'MSB' self.bit_format = 'MSB' self.set_gain(gain) # Think about whether this is necessary. time.sleep(1) def convertFromTwosComplement24bit(self, inputValue): return -(inputValue & 0x800000) + (inputValue & 0x7fffff) def is_ready(self): return GPIO.input(self.DOUT) == 0 def set_gain(self, gain): if gain is 128: self.GAIN = 1 elif gain is 64: self.GAIN = 3 elif gain is 32: self.GAIN = 2 GPIO.output(self.PD_SCK, False) # Read out a set of raw bytes and throw it away. self.readRawBytes() def get_gain(self): if self.GAIN == 1: return 128 if self.GAIN == 3: return 64 if self.GAIN == 2: return 32 # Shouldn't get here. return 0 def readNextBit(self): # Clock HX711 Digital Serial Clock (PD_SCK). DOUT will be # ready 1us after PD_SCK rising edge, so we sample after # lowering PD_SCL, when we know DOUT will be stable. GPIO.output(self.PD_SCK, True) GPIO.output(self.PD_SCK, False) value = GPIO.input(self.DOUT) # Convert Boolean to int and return it. return int(value) def readNextByte(self): byteValue = 0 # Read bits and build the byte from top, or bottom, depending # on whether we are in MSB or LSB bit mode. for x in range(8): if self.bit_format == 'MSB': byteValue <<= 1 byteValue |= self.readNextBit() else: byteValue >>= 1 byteValue |= self.readNextBit() * 0x80 # Return the packed byte. return byteValue def readRawBytes(self): # Wait for and get the Read Lock, incase another thread is already # driving the HX711 serial interface. self.readLock.acquire() # Wait until HX711 is ready for us to read a sample. while not self.is_ready(): pass # Read three bytes of data from the HX711. firstByte = self.readNextByte() secondByte = self.readNextByte() thirdByte = self.readNextByte() # HX711 Channel and gain factor are set by number of bits read # after 24 data bits. for i in range(self.GAIN): # Clock a bit out of the HX711 and throw it away. self.readNextBit() # Release the Read Lock, now that we've finished driving the HX711 # serial interface. self.readLock.release() # Depending on how we're configured, return an orderd list of raw byte # values. if self.byte_format == 'LSB': return [thirdByte, secondByte, firstByte] else: return [firstByte, secondByte, thirdByte] def read_long(self): # Get a sample from the HX711 in the form of raw bytes. dataBytes = self.readRawBytes() if self.DEBUG_PRINTING: print(dataBytes,) # Join the raw bytes into a single 24bit 2s complement value. twosComplementValue = ((dataBytes[0] << 16) | (dataBytes[1] << 8) | dataBytes[2]) if self.DEBUG_PRINTING: print("Twos: 0x%06x" % twosComplementValue) # Convert from 24bit twos-complement to a signed value. signedIntValue = self.convertFromTwosComplement24bit(twosComplementValue) # Record the latest sample value we've read. self.lastVal = signedIntValue # Return the sample value we've read from the HX711. return int(signedIntValue) def read_average(self, times=3): # Make sure we've been asked to take a rational amount of samples. if times <= 0: raise ValueError("HX711()::read_average(): times must >= 1!!") # If we're only average across one value, just read it and return it. if times == 1: return self.read_long() # If we're averaging across a low amount of values, just take the # median. if times < 5: return self.read_median(times) # If we're taking a lot of samples, we'll collect them in a list, remove # the outliers, then take the mean of the remaining set. valueList = [] for x in range(times): valueList += [self.read_long()] valueList.sort() # We'll be trimming 20% of outlier samples from top and bottom of collected set. trimAmount = int(len(valueList) * 0.2) # Trim the edge case values. valueList = valueList[trimAmount:-trimAmount] # Return the mean of remaining samples. return sum(valueList) / len(valueList) # A median-based read method, might help when getting random value spikes # for unknown or CPU-related reasons def read_median(self, times=3): if times <= 0: raise ValueError("HX711::read_median(): times must be greater than zero!") # If times == 1, just return a single reading. if times == 1: return self.read_long() valueList = [] for x in range(times): valueList += [self.read_long()] valueList.sort() # If times is odd we can just take the centre value. if (times & 0x1) == 0x1: return valueList[len(valueList) // 2] else: # If times is even we have to take the arithmetic mean of # the two middle values. midpoint = len(valueList) / 2 return sum(valueList[midpoint:midpoint+2]) / 2.0 # Compatibility function, uses channel A version def get_value(self, times=3): return self.get_value_A(times) def get_value_A(self, times=3): return self.read_median(times) - self.get_offset_A() def get_value_B(self, times=3): # for channel B, we need to set_gain(32) g = self.get_gain() self.set_gain(32) value = self.read_median(times) - self.get_offset_B() self.set_gain(g) return value # Compatibility function, uses channel A version def get_weight(self, times=3): return self.get_weight_A(times) def get_weight_A(self, times=3): value = self.get_value_A(times) value = value / self.REFERENCE_UNIT return value def get_weight_B(self, times=3): value = self.get_value_B(times) value = value / self.REFERENCE_UNIT_B return value # Sets tare for channel A for compatibility purposes def tare(self, times=15): return self.tare_A(times) def tare_A(self, times=15): # Backup REFERENCE_UNIT value backupReferenceUnit = self.get_reference_unit_A() self.set_reference_unit_A(1) value = self.read_average(times) if self.DEBUG_PRINTING: print("Tare A value:", value) self.set_offset_A(value) # Restore the reference unit, now that we've got our offset. self.set_reference_unit_A(backupReferenceUnit) return value def tare_B(self, times=15): # Backup REFERENCE_UNIT value backupReferenceUnit = self.get_reference_unit_B() self.set_reference_unit_B(1) # for channel B, we need to set_gain(32) backupGain = self.get_gain() self.set_gain(32) value = self.read_average(times) if self.DEBUG_PRINTING: print("Tare B value:", value) self.set_offset_B(value) # Restore gain/channel/reference unit settings. self.set_gain(backupGain) self.set_reference_unit_B(backupReferenceUnit) return value def set_reading_format(self, byte_format="LSB", bit_format="MSB"): if byte_format == "LSB": self.byte_format = byte_format elif byte_format == "MSB": self.byte_format = byte_format else: raise ValueError("Unrecognised byte_format: \"%s\"" % byte_format) if bit_format == "LSB": self.bit_format = bit_format elif bit_format == "MSB": self.bit_format = bit_format else: raise ValueError("Unrecognised bitformat: \"%s\"" % bit_format) # sets offset for channel A for compatibility reasons def set_offset(self, offset): self.set_offset_A(offset) def set_offset_A(self, offset): self.OFFSET = offset def set_offset_B(self, offset): self.OFFSET_B = offset def get_offset(self): return self.get_offset_A() def get_offset_A(self): return self.OFFSET def get_offset_B(self): return self.OFFSET_B def set_reference_unit(self, reference_unit): self.set_reference_unit_A(reference_unit) def set_reference_unit_A(self, reference_unit): # Make sure we aren't asked to use an invalid reference unit. if reference_unit == 0: raise ValueError("HX711::set_reference_unit_A() can't accept 0 as a reference unit!") return self.REFERENCE_UNIT = reference_unit def set_reference_unit_B(self, reference_unit): # Make sure we aren't asked to use an invalid reference unit. if reference_unit == 0: raise ValueError("HX711::set_reference_unit_A() can't accept 0 as a reference unit!") return self.REFERENCE_UNIT_B = reference_unit def get_reference_unit(self): return get_reference_unit_A() def get_reference_unit_A(self): return self.REFERENCE_UNIT def get_reference_unit_B(self): return self.REFERENCE_UNIT_B def power_down(self): # Wait for and get the Read Lock, incase another thread is already # driving the HX711 serial interface. self.readLock.acquire() # Cause a rising edge on HX711 Digital Serial Clock (PD_SCK). We then # leave it held up and wait 100 us. After 60us the HX711 should be # powered down. GPIO.output(self.PD_SCK, False) GPIO.output(self.PD_SCK, True) time.sleep(0.0001) # Release the Read Lock, now that we've finished driving the HX711 # serial interface. self.readLock.release() def power_up(self): # Wait for and get the Read Lock, incase another thread is already # driving the HX711 serial interface. self.readLock.acquire() # Lower the HX711 Digital Serial Clock (PD_SCK) line. GPIO.output(self.PD_SCK, False) # Wait 100 us for the HX711 to power back up. time.sleep(0.0001) # Release the Read Lock, now that we've finished driving the HX711 # serial interface. self.readLock.release() # HX711 will now be defaulted to Channel A with gain of 128. If this # isn't what client software has requested from us, take a sample and # throw it away, so that next sample from the HX711 will be from the # correct channel/gain. if self.get_gain() != 128: self.readRawBytes() def reset(self): self.power_down() self.power_up() # EOF - hx711.py